sales@quadrantmeasurements.com

Call Us : +91 9021162481

Tan Delta Bridge

Model : QCTD-A

Description

  • Power Systems
  • HT Transformers
  • Motors
  • Bushings
  • Power Cables
  • Power Capacitors
  • High Voltage Laboratories
  • Generators

Features

  • Automated Measurements of Capacitance and Tan Delta.
  • Laptop based test operations.
  • Temperature Correction for Tan Delta values at 20 Deg C
  • Trend Analysis software for Tan Delta VsTime, Tan Delta Vs Voltage.
  • Robust, reliable and safe construction.
  • Different voltage levels of modelsavailable as per the need of customer5KV, 12KV, 15KV, etc.
  • Help feature include Software Operational manual, technical knowhow of Tan Delta and Application Guide. It helps proper system set-up,connections of various objects with respect to their test modes, knowledge of interpretation of test results.

Technical Specification

PARAMETERRANGE RESOLUTION ACCURACY
CAPACITANCE 10pF - 0.1uF (100nF) 0.01pF0.01pF + 0.3 % of the reading + 1pF (UST)
TAN DELTA 0-100%1.0E-54+ 1.0 % of the reading + 5 X 10
VOLTAGE 0-12 KV AC0.01KV+ 1.0 % of the reading + 1 Digit
CURRENT0-100mA1mA + 2.0 % of the reading + 1 Digit


Model : QCTD‐L

Description

  • Power Systems
  • HT Transformers
  • Motors
  • Bushings
  • Power Cables
  • Power Capacitors
  • High Voltage Laboratories
  • Generators

Features

  • Built‐in Bridge, Power supply &Standard Capacitors.
  • Synchronous, tuned and phasesensitive Null Detector.
  • Test Freq. 80Hz, so as to eliminate influence of static/ magnetic field
  • Three different measurement modescan be conveniently selected by selector switch.
  • Suitable for both ungrounded &grounded objects.
  • Robust, portable design for fieldapplications.

Technical Specification

CAPACITANCE Tan Delta  
RangeRange Accuracy (FSD)
Range 1pF to 0.1uF in 10 ranges 0 to 1%0.0003
Accuracy + 0.2% of range +2pF 0 to 10%0.003
10 to 20%0.005
20 to 30%0.007


Model : QCTD-1K

Description

The Capacitance & Tan Delta Model- QCTD -1Kis transformer arm ratio type Bridge. It is a special development for accurate capacitance and tan delta tests on electrical insulation systems
The Bridge is provided with Modes Selector switch so that once the object is connected; it can be measured in different modes without handling the test leads


Application


Features

  • Both Measurements of Capacitance & Tan Delta built in Power Supply Unit, Standard Capacitor and Balancing Bridge Unit.
  • Provision of calibrator to quickly verify the proper operation and calibration of the bridge.
  • Specially designed for Engineering Colleges LabTest voltage 1000V. This low voltage makes the instrument very safe to operate and easy to understand the concept of Capacitance and Tan Delta testing.
  • Provision of Guard terminal. No external automatic guard potential regulator is required.
  • Three different measurement modes can be conveniently selected by a Selector Switch.
  • Suitable for both grounded as well as ungrounded objects.

Technical Specification



Model : QCTD‐M

Description

  • Power Systems
  • HT Transformers
  • Motors
  • Bushings
  • Power Cables
  • Power Capacitors
  • High Voltage Laboratories
  • Generators

Features

  • DIGITAL DISPLAY for Capacitance and Tan Delta
  • NO NEED of calculation
  • SAVING OF Result and INTERACTIVE DOWNLOADSOFTWARE
  • High Resolution for Tan Delta measurements ‐50.00001 (10)
  • Easy to use
  • Safety Protections incorporated

Technical Specification


topbottom