sales@quadrantmeasurements.com
Call Us : +91 9021162481
Both Aand M series of OLTtesters bring out accurate and repeatable results of measured breakdown voltage.Fast high-voltage switch of time makes it possible to carry out test of dielectric liquids, which are easily destroyedunder such infuences.The internal design of OLTtesters combined with a use of automatic high voltage breakers, cutting of suppliedvoltage if tester’s lid has been opened during the test, provide operator with high level of safety.Testers are fully equipped and are ready for operation right after unpacking. They come with a test vessel (IEC60156 – basic confguration) with VDE 0370 mushroom-shape electrodes. Agap between electrodes is easilyregulated with a use of pass-no pass gauge, which comes in pack.A-series provides with fully automatic test procedure according to selected standard (basically IEC 60156 andGOST6581 settings are preloaded). It has a built-in printer which is able to print a test report after procedure isdone. Test results are saved into non-volatile memory of OLTtester. APC-connectivity makes it easy to collect datafrom OLTtester, save and store them as well as print a fulflled report. Test voltage is being measured directly onelectrodes. This fact combined with a true sine voltage shape (independent from supply voltage shape), increasesrepeatability and accuracy of measurements.M-series provides operator with ultra-simplicity of operation. It doesn’t require any presets. All you need ispressing start button after a test vessel is loaded. Tester will show a breakdown voltage result immediately afterbreakdown occurs.Test vessel for this series goes with magnetic stirrer, which stirs a liquid between two measurements.
Output Voltage | 0-100KV AC |
---|---|
Accuracy | + 1% of FSD + 2 digit |
Resolution | 0.1KV |
Display | 20 x 4 backlit LCD |
Tripping Time | less than 10 micro-seconds |
Power Supply | 230VAC, 50Hz, Single Phase |
Controls | HT ON, HT OFF, Increase, Decrease, |
Oil Cell | Transparent polycarbonate molded |
Printer | Thermal Printer |
Memory | 250 results |
Weight | 40Kg approx |
Set are available either in Manual or Motorized operated mode. Besides motorized auto tranformer regulator for motorized can be operated in manual trough switch
Output Voltage | 0-100KV AC |
---|---|
Accuracy | ± 2% of reading ±1 digit |
Resolution | 1KV |
Display | Analog Meter |
Rate of Rise of Voltage | 2KV/s |
Power Supply | 230VAC, 50Hz, Single Phase |
Controls | HT ON, Increase, Deacrese |
Protections | Interlock for CV Chamber Over load / Over voltage protection |